Repeatable Unit Tests require that the job under test produce deterministic data based on a set of predefined inputs and parameters. Calculations based on the current date are common in DataStage jobs but will cause the output produced by jobs to change depending on the date the job executed. This page outlines practices that can ensure jobs using current date calculations can be tested.
Transformer Stages using CurrentDate(), CurrentTime() or CurrentTimestamp() functions
Unless your date calculation requires an exact date/time a record was being processed, the standard CurrentDate()
, CurrentTime()
and CurrentTimestamp()
functions can be substituted with the DSJobStartDate
, DSJobStartTime
and DSJobStartTimestamp
macros which can be set to a specific value during testing. Add DSJobStartDate
, DSJobStartTime
and/or DSJobStartTimestamp
to the parameters clause of the Unit Test Specification and set the appropriate date and time values used during Unit Testing.
... when: parameters: DSJobStartDate: 2012-01-15 DSJobStartTime: 11:05:01
Be careful when setting DSJobStartTimestamp
in conjunction with either DSJobStartDate
or DSJobStartTime
, the MettleCI Unit Testing feature does not enforce that these parameters are logically consistent.
Ignoring columns which are known to be non-deterministic
Rather than ensuring that a job under test produces deterministic data, you may decide to exclude one or more output columns from Unit Test comparisons. This can be done by adding the columns to be ignored to the then clause of the Unit Test Specification.
given: ... when: ... then: - stage: Transform link: Output path: Transform-Output.csv ignore: - CREATION_DATE - LAST_UPDATED