Parallel Job failed with APT_CombineOperatorController,0: FatalError: Null value on the accessor interfacing to field "column"
Symptom
When running S2PX translated PX jobs it failed with the error message APT_CombineOperatorController,0: FatalError: Null value on the accessor interfacing to field "column"
.
Cause
DataStage older than 11.7.1.4 SP1 has problem handling derivation of the form …
If StrCmp(DSLink.column, "@") = 0 Then
SetNull()
Else
DSLink.column[2, Len(DSLink.column)-1]
Solution
Update your DataStage platform to v11.7.1.4 SP1 or later.
© 2015-2024 Data Migrators Pty Ltd.