Problem

If you start a Server Job Unit Test execution and the job status never changes to the Queued/Running state, or the 'Starting Job...' message does not appear in the job log, then it is likely that the preparation phase of Unit Testing failed and the job execution never started.

Diagnostics

Errors can be diagnosed by looking at the Unit Testing log which is written to <Project Root Directory>/&PH&/DSU.STUB.log on the DataStage engine where <Project Root Directory> is usually $DSHOME/../Projects/<Project Name>/.

Solution

if the error in DSU.STUB.log is related to authentication and UniSessionException

2022-05-11 10:36:26,201 FATAL [TestServerJob] Error running unit testing
com.ascential.uo4j.uniobjects.UniSessionException: The user name provided is incorrect
	at com.ascential.uo4j.uniobjects.UniSession.connect(UniSession.java:261)
	at com.datamigrators.mettle.uv.Bootstrap.universeConnect(Bootstrap.java:265)
	at com.datamigrators.mettle.uv.Bootstrap.main(Bootstrap.java:170)

A common error is that customers forget to add Default Credentials to the engine mapping (the installation step described here). Without these the Java Unit Test Harness can't authenticate with Universe.

The credentials don't need to be dsadm but that is a common choice.

For other errors, the customer will need to verify that they have enabled Unit Tesing of Server Jobs correctly, and dataStage has permission to read to the dm-unittest-harness-<x.x-xxx>.jar