System Time Dependency
Rule name | System Time Dependency |
---|---|
Parallel Job | Yes |
Server Job | - |
Job Sequence | - |
Description | Identifies the use of system time in the job |
Description
Jobs with date logic that reads from the system time make it difficult to perform repeatable/automated testing. Instead of using system date functions, it is recommended that the current date be passed in as a job parameter or derived from one of the DSJobStart*
macros. During unit testing, the job parameter or DSJobStart*
macro can be set to a fixed value. The actual job results can then be compared with the expected results without needing to account for differences due to system time.
Actions
Replace the reference to the system time or date with a Job Parameter of the appropriate type.